Advantages of data fusion. First multivariate curve resolution analysis of fused liquid chromatographic second-order data with dual diode array-fluorescent detection

dc.citation.titleAnalytical Chemistryen
dc.citation.volume89
dc.creatorPellegrino Vidal, Rocío Belén
dc.creatorIbañez, Gabriela Alejandra
dc.creatorEscandar, Graciela Mónica
dc.date.accessioned2018-10-10T16:04:23Z
dc.date.available2018-10-10T16:04:23Z
dc.date.issued2017-02-07
dc.descriptionForthe first time, liquid chromatography-diode array detection (LC-DAD) andliquid-chromatography fluorescence detection (LC-FLD) second-order data,collected in a single chromatographic run, were fused and chemometricallyprocessed for the quantitation of coeluting analytes. Two different experimentalmixtures composed of fluorescent and non-fluorescent endocrine disruptors wereanalyzed. Adequate pretreatment of thematrices before their fusion was crucial to attain reliable results.Multivariate curve resolution-alternating least-squares (MCR-ALS) was appliedto LC-DAD, LC-FLD and fused LC-DAD-FLD data. Althoughdifferent degrees of improvement are observed when comparing the fused matrixresults in relation to those obtained using a single detector, clear benefitsof data fusion are demonstrated through: (1) the obtained limits of detectionin the ranges 2.1?24 ng mL?1 and 0.9?6.3 ng mL?1 for the two evaluated systems and (2) the low relative predictionerrors, below 7% in all cases, indicating goodrecoveries and precision. The feasibility of fusing data andits advantages in the analysis of real samples was successfully assessed through the study of spikedtap, underground and river water samples.es
dc.description.filFil: Pellegrino Vidal, Rocío Belén. Universidad Nacional de Rosario. Facultad de Ciencias Bioquímicas y Farmacéuticas. Instituto de Química Rosario (IQUIR-CONICET); Argentina.
dc.description.filFil: Ibañez, Gabriela Alejandra. Universidad Nacional de Rosario. Facultad de Ciencias Bioquímicas y Farmacéuticas. Instituto de Química Rosario (IQUIR-CONICET); Argentina.
dc.description.filFil: Escandar, Graciela Mónica. Universidad Nacional de Rosario. Facultad de Ciencias Bioquímicas y Farmacéuticas. Instituto de Química Rosario (IQUIR-CONICET); Argentina.
dc.description.sponsorshipUniversidad Nacional de Rosario: Project BIO 237es
dc.description.sponsorshipConsejo Nacional de Investigaciones Científicas y Técnicas (CONICET): Project PIP 0163es
dc.description.sponsorshipAgencia Nacional de Promoción Científica y Tecnológica (ANPCyT): PICT 2013-0136es
dc.formatapplication/pdf
dc.format.extent3029−3035
dc.identifier.issn0003-2700
dc.identifier.urihttp://hdl.handle.net/2133/13112
dc.language.isoenges
dc.publisherAmerican Chemical Societyes
dc.relation.publisherversionhttp://dx.doi.org/10.1021/acs.analchem.6b04720es
dc.rightsopenAccesses
dc.rights.holderPellegrino Vidal, Rocío Belénes
dc.rights.holderIbañez, Gabriela Alejandraes
dc.rights.holderEscandar, Graciela Mónicaes
dc.rights.holderAmerican Chemical Societyes
dc.rights.holderUniversidad Nacional de Rosarioes
dc.rights.textEste documento es la versión de manuscrito aceptado de un trabajo publicado que apareció en su forma final en Analytical Chemistry, copyright © American Chemical Society después de la revisión por pares y la edición técnica por parte del editor. Para acceder al trabajo final editado y publicado, consulte https://pubs.acs.org/doi/abs/10.1021/acs.analchem.6b04720es
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/2.5/ar/*
dc.subjectLiquid Chromatography-diode Array Detectiones
dc.subjectLiquid-chromatography Fluorescence Detectiones
dc.subjectData Fusiones
dc.titleAdvantages of data fusion. First multivariate curve resolution analysis of fused liquid chromatographic second-order data with dual diode array-fluorescent detectiones

Archivos

Bloque original
Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
Advantages of data fusion. First multivariate curve resolution analysis of fused liquid chromatographic second-order data with dual diode array-fluorescent detection 89 2017 3029.pdf
Tamaño:
1.06 MB
Formato:
Adobe Portable Document Format
Descripción:
Versión post print
Bloque de licencias
Mostrando 1 - 1 de 1
Nombre:
license.txt
Tamaño:
3.59 KB
Formato:
Item-specific license agreed upon to submission
Descripción: